wechselrichter zum tesent eingebunden

This commit is contained in:
Nils Reiners
2025-09-14 10:52:50 +02:00
parent 7df61fd6c1
commit 2186c4d7db
10 changed files with 158 additions and 13 deletions

31
SG_ready_schalten.py Normal file
View File

@@ -0,0 +1,31 @@
from pymodbus.client import ModbusTcpClient
def write_coils(ip):
# IP und Port der Wärmepumpe
port = 502
client = ModbusTcpClient(ip, port=port)
if not client.connect():
print("Verbindung zur Wärmepumpe fehlgeschlagen.")
return
try:
# Coil 300 = Kommunikation über Bus aktivieren (1)
response_300 = client.write_coil(300, True)
# Coil 301 = SG Ready Stufe 1 aktivieren (1)
response_301 = client.write_coil(301, False)
# Coil 302 = SG Ready Stufe 2 deaktivieren (0)
response_302 = client.write_coil(302, False)
# Optional: Rückmeldungen prüfen
for addr, resp in zip([300, 301, 302], [response_300, response_301, response_302]):
if resp.isError():
print(f"Fehler beim Schreiben von Coil {addr}: {resp}")
else:
print(f"Coil {addr} erfolgreich geschrieben.")
finally:
client.close()
# Testaufruf mit IP-Adresse deiner Wärmepumpe
write_coils("10.0.0.10") # <-- IP-Adresse hier anpassen

View File

@@ -1 +0,0 @@
,nils,nils-ThinkPad-P52,26.05.2025 20:45,file:///home/nils/.config/libreoffice/4;

View File

@@ -18,7 +18,7 @@ class DataBaseCsv:
writer.writerow(data)
return
# If file exists → read existing header and data
# If file exists → read existing header and modbus_registers
with open(self.filename, mode='r', newline='') as csv_file:
reader = csv.DictReader(csv_file)
existing_fields = reader.fieldnames
@@ -39,7 +39,7 @@ class DataBaseCsv:
for row in existing_data:
writer.writerow({field: row.get(field, '') for field in all_fields})
# Write new data row
# Write new modbus_registers row
writer.writerow({field: data.get(field, '') for field in all_fields})
# Replace original file with updated temporary file

View File

@@ -26,7 +26,7 @@ class HeatPump:
def get_registers(self):
# Excel-Datei mit den Input-Registerinformationen
excel_path = "data/heat_pump_registers.xlsx"
excel_path = "modbus_registers/heat_pump_registers.xlsx"
xls = pd.ExcelFile(excel_path)
df_input_registers = xls.parse('04 Input Register')
@@ -43,7 +43,7 @@ class HeatPump:
for _, row in df_clean.iterrows()
}
def get_data(self):
def get_state(self):
data = {}
data['Zeit'] = time.strftime('%Y-%m-%d %H:%M:%S')
for address, info in self.registers.items():

13
main.py
View File

@@ -5,7 +5,7 @@ from data_base_influx import DataBaseInflux
from heat_pump import HeatPump
from shelly_pro_3m import ShellyPro3m
interval = 10
interval_seconds = 10
db = DataBaseInflux(
url="http://localhost:8086",
@@ -16,11 +16,16 @@ db = DataBaseInflux(
hp = HeatPump(device_name='hp_master', ip_address='10.0.0.10')
shelly = ShellyPro3m(device_name='wohnung_2_6', ip_address='192.168.1.121')
wr = SolarEdgeWechselrichter(device_name='wr_master', ip_address='192.168.1.112')
controller = SgReadyController(hp, wr)
while True:
now = datetime.now()
if now.second % interval == 0 and now.microsecond < 100_000:
db.store_data(hp.device_name, hp.get_data())
db.store_data(shelly.device_name, shelly.get_data())
if now.second % interval_seconds == 0 and now.microsecond < 100_000:
db.store_data(hp.device_name, hp.get_state())
db.store_data(shelly.device_name, shelly.get_state())
db.store_data(wr.device_name, wr.get_state())
controller.perform_action()
time.sleep(0.1)

View File

@@ -18,9 +18,9 @@ class ShellyPro3m:
self.client = ModbusTcpClient(self.ip, port=port)
try:
if not self.client.connect():
print("Verbindung zur Wärmepumpe fehlgeschlagen.")
print("Verbindung zum Shelly-Logger fehlgeschlagen.")
exit(1)
print("Verbindung zur Wärmepumpe erfolgreich.")
print("Verbindung zum Shelly-Logger erfolgreich.")
except KeyboardInterrupt:
print("Beendet durch Benutzer (Ctrl+C).")
finally:
@@ -28,7 +28,7 @@ class ShellyPro3m:
def get_registers(self):
# Excel-Datei mit den Input-Registerinformationen
excel_path = "data/shelly_pro_3m_registers.xlsx"
excel_path = "modbus_registers/shelly_pro_3m_registers.xlsx"
xls = pd.ExcelFile(excel_path)
df_input_registers = xls.parse()
@@ -45,7 +45,7 @@ class ShellyPro3m:
for _, row in df_clean.iterrows()
}
def get_data(self):
def get_state(self):
data = {}
data['Zeit'] = time.strftime('%Y-%m-%d %H:%M:%S')
for address, info in self.registers.items():

110
test_wr.py Normal file
View File

@@ -0,0 +1,110 @@
from pymodbus.client import ModbusTcpClient
import struct
import sys
from typing import Optional
# === Verbindungseinstellungen ===
MODBUS_IP = "192.168.1.107"
MODBUS_PORT = 502 # SetApp: 1502; LCD-Menü: 502 -> ggf. anpassen
UNIT_ID = 1 # Default laut Doku: 1
client = ModbusTcpClient(MODBUS_IP, port=MODBUS_PORT)
if not client.connect():
print("Verbindung fehlgeschlagen.")
sys.exit(1)
def read_regs(addr: int, count: int):
"""Hilfsfunktion: liest 'count' Holding-Register ab base-0 'addr'."""
rr = client.read_holding_registers(address=addr, count=count)
if rr.isError():
return None
return rr.registers
def read_string(addr: int, words: int) -> Optional[str]:
"""
SunSpec-Strings: ASCII, Big-Endian, 2 Bytes pro Register, 0x00 gepadded.
"""
regs = read_regs(addr, words)
if regs is None:
return None
b = b"".join(struct.pack(">H", r) for r in regs)
# SunSpec Strings sind meist mit \x00 und Spaces gepadded:
s = b.decode("ascii", errors="ignore").rstrip("\x00 ").strip()
return s or None
def to_int16(u16: int) -> int:
"""unsigned 16 -> signed 16"""
return struct.unpack(">h", struct.pack(">H", u16))[0]
def apply_sf(raw: int, sf: int) -> float:
return raw * (10 ** sf)
def read_scaled(value_addr: int, sf_addr: int) -> Optional[float]:
regs = read_regs(value_addr, 1)
sf = read_regs(sf_addr, 1)
if regs is None or sf is None:
return None
raw = to_int16(regs[0])
sff = to_int16(sf[0])
return apply_sf(raw, sff)
def read_u32_with_sf(value_addr: int, sf_addr: int) -> Optional[float]:
"""
Liest 32-bit Zähler (acc32, Big-Endian, 2 Register) + SF.
"""
regs = read_regs(value_addr, 2)
sf = read_regs(sf_addr, 1)
if regs is None or sf is None:
return None
# Big-Endian zusammenbauen:
u32 = (regs[0] << 16) | regs[1]
sff = to_int16(sf[0])
return apply_sf(u32, sff)
# ==== Common Block (base-0) ====
manufacturer = read_string(40004, 16) # C_Manufacturer
model = read_string(40020, 16) # C_Model
version = read_string(40044, 8) # C_Version
serial = read_string(40052, 16) # C_SerialNumber
print(f"Hersteller: {manufacturer}")
print(f"Modell: {model}")
print(f"Version: {version}")
print(f"Seriennummer: {serial}")
# ==== Inverter Block (base-0) ====
# AC Power + Scale Factor
ac_power = read_scaled(40083, 40084) # I_AC_Power, I_AC_Power_SF
if ac_power is not None:
print(f"AC Power: {ac_power} W")
else:
print("Fehler beim Lesen von AC Power")
# AC Spannung L-N Durchschnitt (falls 1ph/3ph mit N verfügbar) + SF
ac_voltage = read_scaled(40079, 40082) # I_AC_VoltageAN, I_AC_Voltage_SF
if ac_voltage is not None:
print(f"AC Spannung: {ac_voltage} V")
# AC Frequenz + SF
ac_freq = read_scaled(40085, 40086) # I_AC_Frequency, _SF
if ac_freq is not None:
print(f"Frequenz: {ac_freq} Hz")
# DC Power + SF
dc_power = read_scaled(40100, 40101) # I_DC_Power, _SF
if dc_power is not None:
print(f"DC Power: {dc_power} W")
# Lifetime Energy (AC_Energy_WH, acc32) + SF
lifetime_wh = read_u32_with_sf(40093, 40095) # I_AC_Energy_WH, _SF
if lifetime_wh is not None:
print(f"Lifetime Energy: {lifetime_wh} Wh")
# Status
status_regs = read_regs(40107, 2) # I_Status, I_Status_Vendor
if status_regs:
i_status = status_regs[0]
i_status_vendor = status_regs[1]
print(f"Status: {i_status} (Vendor: {i_status_vendor})")
client.close()