inverter was included
This commit is contained in:
38
README
38
README
@@ -11,10 +11,42 @@ Was needs to be done on the Raspberry pi before the tool can run.
|
||||
- pip install -r requirements.txt
|
||||
|
||||
|
||||
How to run the script:
|
||||
3) How to run the script for testing:
|
||||
|
||||
- nohup python main.py > terminal_log 2>&1 &
|
||||
nohup python main.py > terminal_log 2>&1 &
|
||||
|
||||
For reading out the terminal_log while script is runing:
|
||||
|
||||
- tail -f terminal_log
|
||||
tail -f terminal_log
|
||||
|
||||
|
||||
4) Implement and run the ems as systemd service:
|
||||
create:
|
||||
/etc/systemd/system/allmende_ems.service
|
||||
|
||||
insert:
|
||||
[Unit]
|
||||
Description=Allmende EMS Python Script
|
||||
After=network.target
|
||||
|
||||
[Service]
|
||||
WorkingDirectory=/home/pi/projects/allmende_ems
|
||||
ExecStart=/home/pi/allmende_ems/bin/python3.11 /home/pi/projects/allmende_ems/main.py
|
||||
Restart=always
|
||||
RestartSec=5
|
||||
StandardOutput=journal
|
||||
StandardError=journal
|
||||
|
||||
[Install]
|
||||
WantedBy=multi-user.target
|
||||
|
||||
manage the service with the following commands:
|
||||
Once:
|
||||
sudo systemctl daemon-reload
|
||||
sudo systemctl start allmende_ems.service
|
||||
sudo systemctl enable allmende_ems.service
|
||||
While running:
|
||||
sudo systemctl status allmende_ems.service
|
||||
sudo systemctl restart allmende_ems.service
|
||||
sudo systemctl stop allmende_ems.service
|
||||
journalctl -u allmende_ems.service
|
||||
|
||||
Binary file not shown.
Binary file not shown.
BIN
__pycache__/make_tunnel.cpython-312.pyc
Normal file
BIN
__pycache__/make_tunnel.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/pv_inverter.cpython-312.pyc
Normal file
BIN
__pycache__/pv_inverter.cpython-312.pyc
Normal file
Binary file not shown.
Binary file not shown.
@@ -3,16 +3,17 @@ import pandas as pd
|
||||
import time
|
||||
|
||||
class HeatPump:
|
||||
def __init__(self, device_name: str, ip_address: str):
|
||||
def __init__(self, device_name: str, ip_address: str, port: int=502):
|
||||
self.device_name = device_name
|
||||
self.ip = ip_address
|
||||
self.port = port
|
||||
self.client = None
|
||||
self.connect_to_modbus()
|
||||
self.registers = None
|
||||
self.get_registers()
|
||||
|
||||
def connect_to_modbus(self):
|
||||
port = 502
|
||||
port = self.port
|
||||
self.client = ModbusTcpClient(self.ip, port=port)
|
||||
try:
|
||||
if not self.client.connect():
|
||||
|
||||
14
main.py
14
main.py
@@ -3,22 +3,26 @@ from datetime import datetime
|
||||
from data_base_csv import DataBaseCsv
|
||||
from data_base_influx import DataBaseInflux
|
||||
from heat_pump import HeatPump
|
||||
from pv_inverter import PvInverter
|
||||
from shelly_pro_3m import ShellyPro3m
|
||||
|
||||
# For dev-System run in terminal: ssh -N -L 127.0.0.1:8111:10.0.0.10:502 pi@192.168.1.146
|
||||
# For productive-System change port in heatpump to 502
|
||||
|
||||
interval_seconds = 10
|
||||
|
||||
db = DataBaseInflux(
|
||||
url="http://localhost:8086",
|
||||
url="http://192.168.1.146:8086",
|
||||
token="Cw_naEZyvJ3isiAh1P4Eq3TsjcHmzzDFS7SlbKDsS6ZWL04fMEYixWqtNxGThDdG27S9aW5g7FP9eiq5z1rsGA==",
|
||||
org="allmende",
|
||||
bucket="allmende_db"
|
||||
)
|
||||
|
||||
hp = HeatPump(device_name='hp_master', ip_address='10.0.0.10')
|
||||
hp = HeatPump(device_name='hp_master', ip_address='localhost', port=8111)
|
||||
shelly = ShellyPro3m(device_name='wohnung_2_6', ip_address='192.168.1.121')
|
||||
wr = SolarEdgeWechselrichter(device_name='wr_master', ip_address='192.168.1.112')
|
||||
wr = PvInverter(device_name='wr_master', ip_address='192.168.1.112')
|
||||
|
||||
controller = SgReadyController(hp, wr)
|
||||
#controller = SgReadyController(hp, wr)
|
||||
|
||||
while True:
|
||||
now = datetime.now()
|
||||
@@ -26,6 +30,6 @@ while True:
|
||||
db.store_data(hp.device_name, hp.get_state())
|
||||
db.store_data(shelly.device_name, shelly.get_state())
|
||||
db.store_data(wr.device_name, wr.get_state())
|
||||
controller.perform_action()
|
||||
#controller.perform_action()
|
||||
time.sleep(0.1)
|
||||
|
||||
|
||||
22
make_tunnel.py
Normal file
22
make_tunnel.py
Normal file
@@ -0,0 +1,22 @@
|
||||
from sshtunnel import SSHTunnelForwarder
|
||||
|
||||
# ---- KONFIG ----
|
||||
SSH_HOST = "192.168.1.146" # Raspberry Pi im 192.168.1.x Netz
|
||||
SSH_PORT = 22
|
||||
SSH_USER = "pi"
|
||||
PASSWORD = 'raspberry' # oder Passwort als String
|
||||
|
||||
|
||||
REMOTE_IP = "10.0.0.10" # Wärmepumpe im 10.0.0.x Netz
|
||||
REMOTE_PORT = 502 # Modbus/TCP Port
|
||||
|
||||
def make_tunnel(port):
|
||||
tunnel = SSHTunnelForwarder(
|
||||
(SSH_HOST, SSH_PORT),
|
||||
ssh_username=SSH_USER,
|
||||
ssh_password=PASSWORD,
|
||||
remote_bind_address=(REMOTE_IP, REMOTE_PORT),
|
||||
local_bind_address=("127.0.0.1", port),
|
||||
)
|
||||
tunnel.start()
|
||||
return tunnel
|
||||
BIN
modbus_registers/pv_inverter_registers.xlsx
Normal file
BIN
modbus_registers/pv_inverter_registers.xlsx
Normal file
Binary file not shown.
68
pv_inverter.py
Normal file
68
pv_inverter.py
Normal file
@@ -0,0 +1,68 @@
|
||||
import time
|
||||
import pandas as pd
|
||||
from pymodbus.client import ModbusTcpClient
|
||||
|
||||
class PvInverter:
|
||||
def __init__(self, device_name: str, ip_address: str, port: int = 502, unit: int = 1):
|
||||
self.device_name = device_name
|
||||
self.ip = ip_address
|
||||
self.port = port
|
||||
self.unit = unit
|
||||
self.client = None
|
||||
self.registers = None
|
||||
|
||||
self.connect_to_modbus()
|
||||
self.get_registers()
|
||||
|
||||
def connect_to_modbus(self):
|
||||
# Timeout & retries optional, aber hilfreich:
|
||||
self.client = ModbusTcpClient(self.ip, port=self.port, timeout=3.0, retries=3)
|
||||
if not self.client.connect():
|
||||
print("Verbindung zu Wechselrichter fehlgeschlagen.")
|
||||
raise SystemExit(1)
|
||||
print("Verbindung zu Wechselrichter erfolgreich.")
|
||||
|
||||
# WICHTIG: NICHT hier schließen!
|
||||
# finally: self.client.close() <-- entfernen
|
||||
|
||||
def close(self):
|
||||
if self.client:
|
||||
self.client.close()
|
||||
self.client = None
|
||||
|
||||
def get_registers(self):
|
||||
excel_path = "modbus_registers/pv_inverter_registers.xlsx"
|
||||
xls = pd.ExcelFile(excel_path)
|
||||
df_input_registers = xls.parse()
|
||||
df_clean = df_input_registers[['MB Adresse', 'Beschreibung', 'Variabel Typ']].dropna()
|
||||
df_clean['MB Adresse'] = df_clean['MB Adresse'].astype(int)
|
||||
|
||||
self.registers = {
|
||||
row['MB Adresse']: {
|
||||
'desc': row['Beschreibung'],
|
||||
'type': 'REAL' if str(row['Variabel Typ']).upper() == 'REAL' else 'INT'
|
||||
}
|
||||
for _, row in df_clean.iterrows()
|
||||
}
|
||||
|
||||
def get_state(self):
|
||||
data = {'Zeit': time.strftime('%Y-%m-%d %H:%M:%S')}
|
||||
for address, info in self.registers.items():
|
||||
reg_type = info['type']
|
||||
# Unit-ID mitgeben (wichtig bei pymodbus>=3)
|
||||
result = self.client.read_holding_registers(
|
||||
address=address,
|
||||
count=2 if reg_type == 'REAL' else 1,
|
||||
slave=self.unit # pymodbus 2.x -> 'slave', nicht 'unit'
|
||||
)
|
||||
if result.isError():
|
||||
print(f"Fehler beim Lesen von Adresse {address}: {result}")
|
||||
continue
|
||||
|
||||
# Minimal invasiv: wie bei dir – erstes Register verwenden
|
||||
value = result.registers[0]
|
||||
print(f"Adresse {address} - {info['desc']}: {value}")
|
||||
data[f"{address} - {info['desc']}"] = value
|
||||
return data
|
||||
|
||||
|
||||
@@ -1,3 +1,4 @@
|
||||
pymodbus~=3.8.6
|
||||
pandas
|
||||
openpyxl
|
||||
sshtunnel
|
||||
@@ -5,16 +5,17 @@ import pandas as pd
|
||||
import time
|
||||
|
||||
class ShellyPro3m:
|
||||
def __init__(self, device_name: str, ip_address: str):
|
||||
def __init__(self, device_name: str, ip_address: str, port: int=502):
|
||||
self.device_name = device_name
|
||||
self.ip = ip_address
|
||||
self.port = port
|
||||
self.client = None
|
||||
self.connect_to_modbus()
|
||||
self.registers = None
|
||||
self.get_registers()
|
||||
|
||||
def connect_to_modbus(self):
|
||||
port = 502
|
||||
port = self.port
|
||||
self.client = ModbusTcpClient(self.ip, port=port)
|
||||
try:
|
||||
if not self.client.connect():
|
||||
|
||||
@@ -4,7 +4,7 @@ import sys
|
||||
from typing import Optional
|
||||
|
||||
# === Verbindungseinstellungen ===
|
||||
MODBUS_IP = "192.168.1.107"
|
||||
MODBUS_IP = "192.168.1.112"
|
||||
MODBUS_PORT = 502 # SetApp: 1502; LCD-Menü: 502 -> ggf. anpassen
|
||||
UNIT_ID = 1 # Default laut Doku: 1
|
||||
|
||||
|
||||
Reference in New Issue
Block a user