controller implemented and tested

This commit is contained in:
Nils Reiners
2025-09-25 21:16:51 +02:00
parent 0bcf8a2d8c
commit b066658eb0
12 changed files with 95 additions and 1536 deletions

61
sg_ready_controller.py Normal file
View File

@@ -0,0 +1,61 @@
from pymodbus.client import ModbusTcpClient
class SgReadyController():
def __init__(self, es):
self.es = es
def perform_action(self, heat_pump_name, meter_name, state):
hp = self.es.get_component_by_name(heat_pump_name)
meter_values = state[meter_name]
power_to_grid = meter_values['40206 - M_AC_Power'] * 10 ** meter_values['40210 - M_AC_Power_SF']
if power_to_grid > 10000:
self.switch_sg_ready_mode(hp.ip, hp.port, 'mode2')
elif power_to_grid < 0:
self.switch_sg_ready_mode(hp.ip, hp.port, 'mode1')
def switch_sg_ready_mode(self, ip, port, mode):
"""
Register 300: 1=BUS 0= Hardware Kontakte
Register 301 & 302:
0-0= Kein Offset
0-1 Boiler und Heizung Offset
1-1 Boiler Offset + E-Einsatz Sollwert Erhöht
1-0 SG EVU Sperre
:param ip:
:param mode:
'mode1' = [True, False, False] => SG Ready deactivated
'mode2' = [True, False, True] => SG ready activated for heatpump only
'mode3' = [True, True, True] => SG ready activated for heatpump and heat rod
:return:
"""
client = ModbusTcpClient(ip, port=port)
if not client.connect():
print("Verbindung zur Wärmepumpe fehlgeschlagen.")
return
mode_code = None
if mode == 'mode1':
mode_code = [True, False, False]
elif mode == 'mode2':
mode_code = [True, False, True]
elif mode == 'mode3':
mode_code = [True, True, True]
else:
print('Uncorrect or no string for mode!')
try:
response_300 = client.write_coil(300, mode_code[0])
response_301 = client.write_coil(301, mode_code[1])
response_302 = client.write_coil(302, mode_code[2])
# Optional: Rückmeldungen prüfen
for addr, resp in zip([300, 301, 302], [response_300, response_301, response_302]):
if resp.isError():
print(f"Fehler beim Schreiben von Coil {addr}: {resp}")
else:
print(f"Coil {addr} erfolgreich geschrieben.")
finally:
client.close()