Compare commits
6 Commits
niklas/imp
...
5319a299be
| Author | SHA1 | Date | |
|---|---|---|---|
|
|
5319a299be | ||
|
|
2186c4d7db | ||
|
|
7df61fd6c1 | ||
|
|
0734f7a810 | ||
|
|
65a75e061b | ||
|
|
974ec43f10 |
38
README
38
README
@@ -11,10 +11,42 @@ Was needs to be done on the Raspberry pi before the tool can run.
|
|||||||
- pip install -r requirements.txt
|
- pip install -r requirements.txt
|
||||||
|
|
||||||
|
|
||||||
How to run the script:
|
3) How to run the script for testing:
|
||||||
|
|
||||||
- nohup python main.py > terminal_log 2>&1 &
|
nohup python main.py > terminal_log 2>&1 &
|
||||||
|
|
||||||
For reading out the terminal_log while script is runing:
|
For reading out the terminal_log while script is runing:
|
||||||
|
|
||||||
- tail -f terminal_log
|
tail -f terminal_log
|
||||||
|
|
||||||
|
|
||||||
|
4) Implement and run the ems as systemd service:
|
||||||
|
create:
|
||||||
|
/etc/systemd/system/allmende_ems.service
|
||||||
|
|
||||||
|
insert:
|
||||||
|
[Unit]
|
||||||
|
Description=Allmende EMS Python Script
|
||||||
|
After=network.target
|
||||||
|
|
||||||
|
[Service]
|
||||||
|
WorkingDirectory=/home/pi/projects/allmende_ems
|
||||||
|
ExecStart=/home/pi/allmende_ems/bin/python3.11 /home/pi/projects/allmende_ems/main.py
|
||||||
|
Restart=always
|
||||||
|
RestartSec=5
|
||||||
|
StandardOutput=journal
|
||||||
|
StandardError=journal
|
||||||
|
|
||||||
|
[Install]
|
||||||
|
WantedBy=multi-user.target
|
||||||
|
|
||||||
|
manage the service with the following commands:
|
||||||
|
Once:
|
||||||
|
sudo systemctl daemon-reload
|
||||||
|
sudo systemctl start allmende_ems.service
|
||||||
|
sudo systemctl enable allmende_ems.service
|
||||||
|
While running:
|
||||||
|
sudo systemctl status allmende_ems.service
|
||||||
|
sudo systemctl restart allmende_ems.service
|
||||||
|
sudo systemctl stop allmende_ems.service
|
||||||
|
journalctl -u allmende_ems.service
|
||||||
|
|||||||
31
SG_ready_schalten.py
Normal file
31
SG_ready_schalten.py
Normal file
@@ -0,0 +1,31 @@
|
|||||||
|
from pymodbus.client import ModbusTcpClient
|
||||||
|
|
||||||
|
def write_coils(ip):
|
||||||
|
# IP und Port der Wärmepumpe
|
||||||
|
port = 502
|
||||||
|
client = ModbusTcpClient(ip, port=port)
|
||||||
|
|
||||||
|
if not client.connect():
|
||||||
|
print("Verbindung zur Wärmepumpe fehlgeschlagen.")
|
||||||
|
return
|
||||||
|
|
||||||
|
try:
|
||||||
|
# Coil 300 = Kommunikation über Bus aktivieren (1)
|
||||||
|
response_300 = client.write_coil(300, True)
|
||||||
|
# Coil 301 = SG Ready Stufe 1 aktivieren (1)
|
||||||
|
response_301 = client.write_coil(301, False)
|
||||||
|
# Coil 302 = SG Ready Stufe 2 deaktivieren (0)
|
||||||
|
response_302 = client.write_coil(302, False)
|
||||||
|
|
||||||
|
# Optional: Rückmeldungen prüfen
|
||||||
|
for addr, resp in zip([300, 301, 302], [response_300, response_301, response_302]):
|
||||||
|
if resp.isError():
|
||||||
|
print(f"Fehler beim Schreiben von Coil {addr}: {resp}")
|
||||||
|
else:
|
||||||
|
print(f"Coil {addr} erfolgreich geschrieben.")
|
||||||
|
|
||||||
|
finally:
|
||||||
|
client.close()
|
||||||
|
|
||||||
|
# Testaufruf mit IP-Adresse deiner Wärmepumpe
|
||||||
|
write_coils("10.0.0.10") # <-- IP-Adresse hier anpassen
|
||||||
BIN
__pycache__/data_base_csv.cpython-312.pyc
Normal file
BIN
__pycache__/data_base_csv.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/data_base_influx.cpython-311.pyc
Normal file
BIN
__pycache__/data_base_influx.cpython-311.pyc
Normal file
Binary file not shown.
BIN
__pycache__/data_base_influx.cpython-312.pyc
Normal file
BIN
__pycache__/data_base_influx.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/heat_pump.cpython-312.pyc
Normal file
BIN
__pycache__/heat_pump.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/make_tunnel.cpython-312.pyc
Normal file
BIN
__pycache__/make_tunnel.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/pv_inverter.cpython-312.pyc
Normal file
BIN
__pycache__/pv_inverter.cpython-312.pyc
Normal file
Binary file not shown.
BIN
__pycache__/shelly_pro_3m.cpython-312.pyc
Normal file
BIN
__pycache__/shelly_pro_3m.cpython-312.pyc
Normal file
Binary file not shown.
@@ -18,7 +18,7 @@ class DataBaseCsv:
|
|||||||
writer.writerow(data)
|
writer.writerow(data)
|
||||||
return
|
return
|
||||||
|
|
||||||
# If file exists → read existing header and data
|
# If file exists → read existing header and modbus_registers
|
||||||
with open(self.filename, mode='r', newline='') as csv_file:
|
with open(self.filename, mode='r', newline='') as csv_file:
|
||||||
reader = csv.DictReader(csv_file)
|
reader = csv.DictReader(csv_file)
|
||||||
existing_fields = reader.fieldnames
|
existing_fields = reader.fieldnames
|
||||||
@@ -39,7 +39,7 @@ class DataBaseCsv:
|
|||||||
for row in existing_data:
|
for row in existing_data:
|
||||||
writer.writerow({field: row.get(field, '') for field in all_fields})
|
writer.writerow({field: row.get(field, '') for field in all_fields})
|
||||||
|
|
||||||
# Write new data row
|
# Write new modbus_registers row
|
||||||
writer.writerow({field: data.get(field, '') for field in all_fields})
|
writer.writerow({field: data.get(field, '') for field in all_fields})
|
||||||
|
|
||||||
# Replace original file with updated temporary file
|
# Replace original file with updated temporary file
|
||||||
|
|||||||
28
data_base_influx.py
Normal file
28
data_base_influx.py
Normal file
@@ -0,0 +1,28 @@
|
|||||||
|
from influxdb_client import InfluxDBClient, Point, WritePrecision
|
||||||
|
from datetime import datetime
|
||||||
|
|
||||||
|
class DataBaseInflux:
|
||||||
|
def __init__(self, url: str, token: str, org: str, bucket: str):
|
||||||
|
self.url = url
|
||||||
|
self.token = token
|
||||||
|
self.org = org
|
||||||
|
self.bucket = bucket
|
||||||
|
self.client = InfluxDBClient(url=self.url, token=self.token, org=self.org)
|
||||||
|
self.write_api = self.client.write_api()
|
||||||
|
|
||||||
|
def store_data(self, device_name: str, data: dict):
|
||||||
|
measurement = device_name # Fest auf "messungen" gesetzt
|
||||||
|
|
||||||
|
point = Point(measurement)
|
||||||
|
|
||||||
|
# Alle Key/Value-Paare als Fields speichern
|
||||||
|
for key, value in data.items():
|
||||||
|
point = point.field(key, value)
|
||||||
|
|
||||||
|
# Zeitstempel automatisch auf jetzt setzen
|
||||||
|
point = point.time(datetime.utcnow(), WritePrecision.NS)
|
||||||
|
|
||||||
|
# Punkt in InfluxDB schreiben
|
||||||
|
self.write_api.write(bucket=self.bucket, org=self.org, record=point)
|
||||||
|
|
||||||
|
|
||||||
10
heat_pump.py
10
heat_pump.py
@@ -3,15 +3,17 @@ import pandas as pd
|
|||||||
import time
|
import time
|
||||||
|
|
||||||
class HeatPump:
|
class HeatPump:
|
||||||
def __init__(self, ip_address: str):
|
def __init__(self, device_name: str, ip_address: str, port: int=502):
|
||||||
|
self.device_name = device_name
|
||||||
self.ip = ip_address
|
self.ip = ip_address
|
||||||
|
self.port = port
|
||||||
self.client = None
|
self.client = None
|
||||||
self.connect_to_modbus()
|
self.connect_to_modbus()
|
||||||
self.registers = None
|
self.registers = None
|
||||||
self.get_registers()
|
self.get_registers()
|
||||||
|
|
||||||
def connect_to_modbus(self):
|
def connect_to_modbus(self):
|
||||||
port = 502
|
port = self.port
|
||||||
self.client = ModbusTcpClient(self.ip, port=port)
|
self.client = ModbusTcpClient(self.ip, port=port)
|
||||||
try:
|
try:
|
||||||
if not self.client.connect():
|
if not self.client.connect():
|
||||||
@@ -25,7 +27,7 @@ class HeatPump:
|
|||||||
|
|
||||||
def get_registers(self):
|
def get_registers(self):
|
||||||
# Excel-Datei mit den Input-Registerinformationen
|
# Excel-Datei mit den Input-Registerinformationen
|
||||||
excel_path = "data/ModBus TCPIP 1.17(1).xlsx"
|
excel_path = "modbus_registers/heat_pump_registers.xlsx"
|
||||||
xls = pd.ExcelFile(excel_path)
|
xls = pd.ExcelFile(excel_path)
|
||||||
df_input_registers = xls.parse('04 Input Register')
|
df_input_registers = xls.parse('04 Input Register')
|
||||||
|
|
||||||
@@ -42,7 +44,7 @@ class HeatPump:
|
|||||||
for _, row in df_clean.iterrows()
|
for _, row in df_clean.iterrows()
|
||||||
}
|
}
|
||||||
|
|
||||||
def get_data(self):
|
def get_state(self):
|
||||||
data = {}
|
data = {}
|
||||||
data['Zeit'] = time.strftime('%Y-%m-%d %H:%M:%S')
|
data['Zeit'] = time.strftime('%Y-%m-%d %H:%M:%S')
|
||||||
for address, info in self.registers.items():
|
for address, info in self.registers.items():
|
||||||
|
|||||||
30
main.py
30
main.py
@@ -1,17 +1,35 @@
|
|||||||
import time
|
import time
|
||||||
from datetime import datetime
|
from datetime import datetime
|
||||||
from data_base_csv import DataBaseCsv
|
from data_base_csv import DataBaseCsv
|
||||||
|
from data_base_influx import DataBaseInflux
|
||||||
from heat_pump import HeatPump
|
from heat_pump import HeatPump
|
||||||
|
from pv_inverter import PvInverter
|
||||||
|
from shelly_pro_3m import ShellyPro3m
|
||||||
|
|
||||||
interval = 10 # z.B. alle 10 Sekunden
|
# For dev-System run in terminal: ssh -N -L 127.0.0.1:8111:10.0.0.10:502 pi@192.168.1.146
|
||||||
|
# For productive-System change port in heatpump to 502
|
||||||
|
|
||||||
db = DataBaseCsv('modbus_log.csv')
|
interval_seconds = 10
|
||||||
hp = HeatPump(ip_address='10.0.0.10')
|
|
||||||
|
db = DataBaseInflux(
|
||||||
|
url="http://192.168.1.146:8086",
|
||||||
|
token="Cw_naEZyvJ3isiAh1P4Eq3TsjcHmzzDFS7SlbKDsS6ZWL04fMEYixWqtNxGThDdG27S9aW5g7FP9eiq5z1rsGA==",
|
||||||
|
org="allmende",
|
||||||
|
bucket="allmende_db"
|
||||||
|
)
|
||||||
|
|
||||||
|
hp = HeatPump(device_name='hp_master', ip_address='localhost', port=8111)
|
||||||
|
shelly = ShellyPro3m(device_name='wohnung_2_6', ip_address='192.168.1.121')
|
||||||
|
wr = PvInverter(device_name='wr_master', ip_address='192.168.1.112')
|
||||||
|
|
||||||
|
#controller = SgReadyController(hp, wr)
|
||||||
|
|
||||||
while True:
|
while True:
|
||||||
now = datetime.now()
|
now = datetime.now()
|
||||||
if now.second % interval == 0 and now.microsecond < 100_000:
|
if now.second % interval_seconds == 0 and now.microsecond < 100_000:
|
||||||
db.store_data(hp.get_data())
|
db.store_data(hp.device_name, hp.get_state())
|
||||||
|
db.store_data(shelly.device_name, shelly.get_state())
|
||||||
|
db.store_data(wr.device_name, wr.get_state())
|
||||||
|
#controller.perform_action()
|
||||||
time.sleep(0.1)
|
time.sleep(0.1)
|
||||||
|
|
||||||
|
|||||||
22
make_tunnel.py
Normal file
22
make_tunnel.py
Normal file
@@ -0,0 +1,22 @@
|
|||||||
|
from sshtunnel import SSHTunnelForwarder
|
||||||
|
|
||||||
|
# ---- KONFIG ----
|
||||||
|
SSH_HOST = "192.168.1.146" # Raspberry Pi im 192.168.1.x Netz
|
||||||
|
SSH_PORT = 22
|
||||||
|
SSH_USER = "pi"
|
||||||
|
PASSWORD = 'raspberry' # oder Passwort als String
|
||||||
|
|
||||||
|
|
||||||
|
REMOTE_IP = "10.0.0.10" # Wärmepumpe im 10.0.0.x Netz
|
||||||
|
REMOTE_PORT = 502 # Modbus/TCP Port
|
||||||
|
|
||||||
|
def make_tunnel(port):
|
||||||
|
tunnel = SSHTunnelForwarder(
|
||||||
|
(SSH_HOST, SSH_PORT),
|
||||||
|
ssh_username=SSH_USER,
|
||||||
|
ssh_password=PASSWORD,
|
||||||
|
remote_bind_address=(REMOTE_IP, REMOTE_PORT),
|
||||||
|
local_bind_address=("127.0.0.1", port),
|
||||||
|
)
|
||||||
|
tunnel.start()
|
||||||
|
return tunnel
|
||||||
BIN
modbus_registers/pv_inverter_registers.xlsx
Normal file
BIN
modbus_registers/pv_inverter_registers.xlsx
Normal file
Binary file not shown.
BIN
modbus_registers/shelly_pro_3m_registers.xlsx
Normal file
BIN
modbus_registers/shelly_pro_3m_registers.xlsx
Normal file
Binary file not shown.
41
plot_data.py
Normal file
41
plot_data.py
Normal file
@@ -0,0 +1,41 @@
|
|||||||
|
# Neu laden nach Code-Reset
|
||||||
|
import pandas as pd
|
||||||
|
import matplotlib.pyplot as plt
|
||||||
|
|
||||||
|
# Pfad zur neu hochgeladenen Datei
|
||||||
|
file_path = "modbus_log.csv"
|
||||||
|
df_new = pd.read_csv(file_path)
|
||||||
|
|
||||||
|
# Zeitstempel in datetime konvertieren
|
||||||
|
df_new['Zeit'] = pd.to_datetime(df_new['Zeit'])
|
||||||
|
|
||||||
|
# Spaltenbezeichnungen für den Plot
|
||||||
|
registers = [
|
||||||
|
'10 - Gebäudeseite Wärmepumpe Vorlauf/Austritt (Warm)',
|
||||||
|
'11 - Gebäudeseite Wärmepumpe Rücklauf/Eintritt (Kalt)',
|
||||||
|
'12 - Umweltseite/Quelle Wärmepumpe Eintritt (Warm)',
|
||||||
|
'13 - Umweltseite/Quelle Wärmepumpe Austritt (Kalt)',
|
||||||
|
'50 - Rücklauftemperatur Direkterheizkreis oder Puffertemperatur',
|
||||||
|
'70 - Vorlauftemperatur Mischerkreis 1',
|
||||||
|
'150 - Trinkwarmwasserspiecher oben (Ein)',
|
||||||
|
'153 - Trinkwarmwasserspiecher unten (Aus)'
|
||||||
|
]
|
||||||
|
all_registers = ['300 - Aussentemperatur'] + registers
|
||||||
|
|
||||||
|
# Plot erzeugen
|
||||||
|
plt.figure(figsize=(14, 8))
|
||||||
|
|
||||||
|
for reg in all_registers:
|
||||||
|
plt.plot(df_new['Zeit'], df_new[reg], label=reg)
|
||||||
|
|
||||||
|
plt.title("Temperaturverläufe inkl. Außentemperatur (neue Daten)")
|
||||||
|
plt.xlabel("Zeit")
|
||||||
|
plt.ylabel("Temperatur (°C)")
|
||||||
|
plt.grid(True)
|
||||||
|
plt.tight_layout()
|
||||||
|
|
||||||
|
# Legende außerhalb des Plots platzieren
|
||||||
|
plt.legend(loc='center left', bbox_to_anchor=(1.0, 0.5))
|
||||||
|
plt.subplots_adjust(right=0.75)
|
||||||
|
|
||||||
|
plt.show()
|
||||||
68
pv_inverter.py
Normal file
68
pv_inverter.py
Normal file
@@ -0,0 +1,68 @@
|
|||||||
|
import time
|
||||||
|
import pandas as pd
|
||||||
|
from pymodbus.client import ModbusTcpClient
|
||||||
|
|
||||||
|
class PvInverter:
|
||||||
|
def __init__(self, device_name: str, ip_address: str, port: int = 502, unit: int = 1):
|
||||||
|
self.device_name = device_name
|
||||||
|
self.ip = ip_address
|
||||||
|
self.port = port
|
||||||
|
self.unit = unit
|
||||||
|
self.client = None
|
||||||
|
self.registers = None
|
||||||
|
|
||||||
|
self.connect_to_modbus()
|
||||||
|
self.get_registers()
|
||||||
|
|
||||||
|
def connect_to_modbus(self):
|
||||||
|
# Timeout & retries optional, aber hilfreich:
|
||||||
|
self.client = ModbusTcpClient(self.ip, port=self.port, timeout=3.0, retries=3)
|
||||||
|
if not self.client.connect():
|
||||||
|
print("Verbindung zu Wechselrichter fehlgeschlagen.")
|
||||||
|
raise SystemExit(1)
|
||||||
|
print("Verbindung zu Wechselrichter erfolgreich.")
|
||||||
|
|
||||||
|
# WICHTIG: NICHT hier schließen!
|
||||||
|
# finally: self.client.close() <-- entfernen
|
||||||
|
|
||||||
|
def close(self):
|
||||||
|
if self.client:
|
||||||
|
self.client.close()
|
||||||
|
self.client = None
|
||||||
|
|
||||||
|
def get_registers(self):
|
||||||
|
excel_path = "modbus_registers/pv_inverter_registers.xlsx"
|
||||||
|
xls = pd.ExcelFile(excel_path)
|
||||||
|
df_input_registers = xls.parse()
|
||||||
|
df_clean = df_input_registers[['MB Adresse', 'Beschreibung', 'Variabel Typ']].dropna()
|
||||||
|
df_clean['MB Adresse'] = df_clean['MB Adresse'].astype(int)
|
||||||
|
|
||||||
|
self.registers = {
|
||||||
|
row['MB Adresse']: {
|
||||||
|
'desc': row['Beschreibung'],
|
||||||
|
'type': 'REAL' if str(row['Variabel Typ']).upper() == 'REAL' else 'INT'
|
||||||
|
}
|
||||||
|
for _, row in df_clean.iterrows()
|
||||||
|
}
|
||||||
|
|
||||||
|
def get_state(self):
|
||||||
|
data = {'Zeit': time.strftime('%Y-%m-%d %H:%M:%S')}
|
||||||
|
for address, info in self.registers.items():
|
||||||
|
reg_type = info['type']
|
||||||
|
# Unit-ID mitgeben (wichtig bei pymodbus>=3)
|
||||||
|
result = self.client.read_holding_registers(
|
||||||
|
address=address,
|
||||||
|
count=2 if reg_type == 'REAL' else 1,
|
||||||
|
slave=self.unit # pymodbus 2.x -> 'slave', nicht 'unit'
|
||||||
|
)
|
||||||
|
if result.isError():
|
||||||
|
print(f"Fehler beim Lesen von Adresse {address}: {result}")
|
||||||
|
continue
|
||||||
|
|
||||||
|
# Minimal invasiv: wie bei dir – erstes Register verwenden
|
||||||
|
value = result.registers[0]
|
||||||
|
print(f"Adresse {address} - {info['desc']}: {value}")
|
||||||
|
data[f"{address} - {info['desc']}"] = value
|
||||||
|
return data
|
||||||
|
|
||||||
|
|
||||||
@@ -1,3 +1,4 @@
|
|||||||
pymodbus~=3.8.6
|
pymodbus~=3.8.6
|
||||||
pandas
|
pandas
|
||||||
openpyxl
|
openpyxl
|
||||||
|
sshtunnel
|
||||||
64
shelly_pro_3m.py
Normal file
64
shelly_pro_3m.py
Normal file
@@ -0,0 +1,64 @@
|
|||||||
|
import struct
|
||||||
|
|
||||||
|
from pymodbus.client import ModbusTcpClient
|
||||||
|
import pandas as pd
|
||||||
|
import time
|
||||||
|
|
||||||
|
class ShellyPro3m:
|
||||||
|
def __init__(self, device_name: str, ip_address: str, port: int=502):
|
||||||
|
self.device_name = device_name
|
||||||
|
self.ip = ip_address
|
||||||
|
self.port = port
|
||||||
|
self.client = None
|
||||||
|
self.connect_to_modbus()
|
||||||
|
self.registers = None
|
||||||
|
self.get_registers()
|
||||||
|
|
||||||
|
def connect_to_modbus(self):
|
||||||
|
port = self.port
|
||||||
|
self.client = ModbusTcpClient(self.ip, port=port)
|
||||||
|
try:
|
||||||
|
if not self.client.connect():
|
||||||
|
print("Verbindung zum Shelly-Logger fehlgeschlagen.")
|
||||||
|
exit(1)
|
||||||
|
print("Verbindung zum Shelly-Logger erfolgreich.")
|
||||||
|
except KeyboardInterrupt:
|
||||||
|
print("Beendet durch Benutzer (Ctrl+C).")
|
||||||
|
finally:
|
||||||
|
self.client.close()
|
||||||
|
|
||||||
|
def get_registers(self):
|
||||||
|
# Excel-Datei mit den Input-Registerinformationen
|
||||||
|
excel_path = "modbus_registers/shelly_pro_3m_registers.xlsx"
|
||||||
|
xls = pd.ExcelFile(excel_path)
|
||||||
|
df_input_registers = xls.parse()
|
||||||
|
|
||||||
|
# Relevante Spalten bereinigen
|
||||||
|
df_clean = df_input_registers[['MB Adresse', 'Beschreibung', 'Variabel Typ']].dropna()
|
||||||
|
df_clean['MB Adresse'] = df_clean['MB Adresse'].astype(int)
|
||||||
|
|
||||||
|
# Dictionary aus Excel erzeugen
|
||||||
|
self.registers = {
|
||||||
|
row['MB Adresse']: {
|
||||||
|
'desc': row['Beschreibung'],
|
||||||
|
'type': 'REAL' if row['Variabel Typ'] == 'REAL' else 'INT'
|
||||||
|
}
|
||||||
|
for _, row in df_clean.iterrows()
|
||||||
|
}
|
||||||
|
|
||||||
|
def get_state(self):
|
||||||
|
data = {}
|
||||||
|
data['Zeit'] = time.strftime('%Y-%m-%d %H:%M:%S')
|
||||||
|
for address, info in self.registers.items():
|
||||||
|
reg_type = info['type']
|
||||||
|
result = self.client.read_input_registers(address, count=2 if reg_type == 'REAL' else 1)
|
||||||
|
if result.isError():
|
||||||
|
print(f"Fehler beim Lesen von Adresse {address}: {result}")
|
||||||
|
continue
|
||||||
|
|
||||||
|
packed = struct.pack(">HH", result.registers[1], result.registers[0])
|
||||||
|
value = round(struct.unpack(">f", packed)[0], 2)
|
||||||
|
|
||||||
|
print(f"Adresse {address} - {info['desc']}: {value}")
|
||||||
|
data[f"{address} - {info['desc']}"] = value
|
||||||
|
return data
|
||||||
52759
terminal_log
52759
terminal_log
File diff suppressed because it is too large
Load Diff
110
test_wr.py
Normal file
110
test_wr.py
Normal file
@@ -0,0 +1,110 @@
|
|||||||
|
from pymodbus.client import ModbusTcpClient
|
||||||
|
import struct
|
||||||
|
import sys
|
||||||
|
from typing import Optional
|
||||||
|
|
||||||
|
# === Verbindungseinstellungen ===
|
||||||
|
MODBUS_IP = "192.168.1.112"
|
||||||
|
MODBUS_PORT = 502 # SetApp: 1502; LCD-Menü: 502 -> ggf. anpassen
|
||||||
|
UNIT_ID = 1 # Default laut Doku: 1
|
||||||
|
|
||||||
|
client = ModbusTcpClient(MODBUS_IP, port=MODBUS_PORT)
|
||||||
|
if not client.connect():
|
||||||
|
print("Verbindung fehlgeschlagen.")
|
||||||
|
sys.exit(1)
|
||||||
|
|
||||||
|
def read_regs(addr: int, count: int):
|
||||||
|
"""Hilfsfunktion: liest 'count' Holding-Register ab base-0 'addr'."""
|
||||||
|
rr = client.read_holding_registers(address=addr, count=count)
|
||||||
|
if rr.isError():
|
||||||
|
return None
|
||||||
|
return rr.registers
|
||||||
|
|
||||||
|
def read_string(addr: int, words: int) -> Optional[str]:
|
||||||
|
"""
|
||||||
|
SunSpec-Strings: ASCII, Big-Endian, 2 Bytes pro Register, 0x00 gepadded.
|
||||||
|
"""
|
||||||
|
regs = read_regs(addr, words)
|
||||||
|
if regs is None:
|
||||||
|
return None
|
||||||
|
b = b"".join(struct.pack(">H", r) for r in regs)
|
||||||
|
# SunSpec Strings sind meist mit \x00 und Spaces gepadded:
|
||||||
|
s = b.decode("ascii", errors="ignore").rstrip("\x00 ").strip()
|
||||||
|
return s or None
|
||||||
|
|
||||||
|
def to_int16(u16: int) -> int:
|
||||||
|
"""unsigned 16 -> signed 16"""
|
||||||
|
return struct.unpack(">h", struct.pack(">H", u16))[0]
|
||||||
|
|
||||||
|
def apply_sf(raw: int, sf: int) -> float:
|
||||||
|
return raw * (10 ** sf)
|
||||||
|
|
||||||
|
def read_scaled(value_addr: int, sf_addr: int) -> Optional[float]:
|
||||||
|
regs = read_regs(value_addr, 1)
|
||||||
|
sf = read_regs(sf_addr, 1)
|
||||||
|
if regs is None or sf is None:
|
||||||
|
return None
|
||||||
|
raw = to_int16(regs[0])
|
||||||
|
sff = to_int16(sf[0])
|
||||||
|
return apply_sf(raw, sff)
|
||||||
|
|
||||||
|
def read_u32_with_sf(value_addr: int, sf_addr: int) -> Optional[float]:
|
||||||
|
"""
|
||||||
|
Liest 32-bit Zähler (acc32, Big-Endian, 2 Register) + SF.
|
||||||
|
"""
|
||||||
|
regs = read_regs(value_addr, 2)
|
||||||
|
sf = read_regs(sf_addr, 1)
|
||||||
|
if regs is None or sf is None:
|
||||||
|
return None
|
||||||
|
# Big-Endian zusammenbauen:
|
||||||
|
u32 = (regs[0] << 16) | regs[1]
|
||||||
|
sff = to_int16(sf[0])
|
||||||
|
return apply_sf(u32, sff)
|
||||||
|
|
||||||
|
# ==== Common Block (base-0) ====
|
||||||
|
manufacturer = read_string(40004, 16) # C_Manufacturer
|
||||||
|
model = read_string(40020, 16) # C_Model
|
||||||
|
version = read_string(40044, 8) # C_Version
|
||||||
|
serial = read_string(40052, 16) # C_SerialNumber
|
||||||
|
|
||||||
|
print(f"Hersteller: {manufacturer}")
|
||||||
|
print(f"Modell: {model}")
|
||||||
|
print(f"Version: {version}")
|
||||||
|
print(f"Seriennummer: {serial}")
|
||||||
|
|
||||||
|
# ==== Inverter Block (base-0) ====
|
||||||
|
# AC Power + Scale Factor
|
||||||
|
ac_power = read_scaled(40083, 40084) # I_AC_Power, I_AC_Power_SF
|
||||||
|
if ac_power is not None:
|
||||||
|
print(f"AC Power: {ac_power} W")
|
||||||
|
else:
|
||||||
|
print("Fehler beim Lesen von AC Power")
|
||||||
|
|
||||||
|
# AC Spannung L-N Durchschnitt (falls 1ph/3ph mit N verfügbar) + SF
|
||||||
|
ac_voltage = read_scaled(40079, 40082) # I_AC_VoltageAN, I_AC_Voltage_SF
|
||||||
|
if ac_voltage is not None:
|
||||||
|
print(f"AC Spannung: {ac_voltage} V")
|
||||||
|
|
||||||
|
# AC Frequenz + SF
|
||||||
|
ac_freq = read_scaled(40085, 40086) # I_AC_Frequency, _SF
|
||||||
|
if ac_freq is not None:
|
||||||
|
print(f"Frequenz: {ac_freq} Hz")
|
||||||
|
|
||||||
|
# DC Power + SF
|
||||||
|
dc_power = read_scaled(40100, 40101) # I_DC_Power, _SF
|
||||||
|
if dc_power is not None:
|
||||||
|
print(f"DC Power: {dc_power} W")
|
||||||
|
|
||||||
|
# Lifetime Energy (AC_Energy_WH, acc32) + SF
|
||||||
|
lifetime_wh = read_u32_with_sf(40093, 40095) # I_AC_Energy_WH, _SF
|
||||||
|
if lifetime_wh is not None:
|
||||||
|
print(f"Lifetime Energy: {lifetime_wh} Wh")
|
||||||
|
|
||||||
|
# Status
|
||||||
|
status_regs = read_regs(40107, 2) # I_Status, I_Status_Vendor
|
||||||
|
if status_regs:
|
||||||
|
i_status = status_regs[0]
|
||||||
|
i_status_vendor = status_regs[1]
|
||||||
|
print(f"Status: {i_status} (Vendor: {i_status_vendor})")
|
||||||
|
|
||||||
|
client.close()
|
||||||
Reference in New Issue